SINGLE MODE FIBRE SPECIFICATIONS (ITU- T G.652)

S.NO.

CHARACTERSTICS TO BE TESTED/VERIFIED

UNIT

REQUIREMENT

      1.        TRANSMISSION

A

Attenuation at

 

                       

 

1310 nm

dB /km

<= 0.34

 

1550nm

dB/km

<= 0.21

B

Spectral Attn. At

 

 

 

1285-1330 nm

dB/km

<= 0.38

 

1383 ± 3nm

dB/km

<= 1.0

C

Point Discontinuity

dB/km

<=0.10

D

Cut off wave length

nm

1160 -1320

E

Mode field diameter (SMMC)

µm

9.3 ± 0.5

F

Dispersion at

 

 

 

1270-1340 nm

ps/nm2.km

<= 5.30

 

1285-1330nm

ps/nm2.km

< =3.50

 

1550

ps/nm2.km

< =18.0

 

Dispersion slope

ps/nm2.km

< =0.092

 

Zero dispersion wave length

nm

1300 –1324

G

PMD (1310nm & 1550nm)

ps/sqrt(Km)

<=0.2

      2.        FIBRE GEOMETRY

A

Clad dia.

µm

125 ± 1.0

B

Clad non-circularity

%

< =1.0

C

Core / Clad Conc.

      µm

<= 0.8

D

Coating  Diameter (UV Acrylate material)

µm

245±10

E

Coating / Clad  Conc.

µm

<= 12

      3.         MECHANICAL TESTS

A

Proof test at min. strain level

%

1

B

Fibre Curl

m

>=4

C

Strippablity test  to remove secondary coating of the fibre

N

1.3<=F<=8.9

D

Dynamic Tensile Strength           Unaged

                                                 
 
                                           Aged

 

 >=550Kpsi
(3.8 G.pa)

>=440Kpsi
  (3.00 G.pa)

E

Static Fatigue

 

>=20

F

Dynamic Fatigue

 

>=20

G

Change in Attenuation at 1550nm when fibre is coiled Nim 1 turn on 32.5+/-0.5 mm diameter mandrel (Microbend Test)

      dB

<=0.5

H

Change in Attenuation measured at 1550 nm when fibre is coiled with 100 turns on 30±0.5mm radius mandrel (Macrobend Test)

      dB

<=0.1

 

 

      4.         ENVIRONMENT TESTS

 

Induced attenuation at 1310nm & 1550 nm

 

 

A

Temp/ Cycling (-60 deg C to +85 deg C)

dB/km

<=0.05

B

Temp. Humidity Cycling 30 days ( -10 deg C to +85 deg C upto 95 % RH)

dB/km

<=0.05

C

Heat Ageing test for 30 days (85 deg C)

dB/km

<=0.05

D

Water Immersion test for 30 days (23 ± 5 deg C)

dB/km

<=0.05